1. Before Using

  This flash is a very precise photographic equipment, there fore don't forget to read this operation manual very carefully before using.

 

1. Please read Operation Manual before using it.

2. Input voltage should be checked before use.

3. Don't move or shock when power on.  Coil of modeling lamp might be cut off.

    In case that it moves with lamp on.

4. Connect to the properly functioning and grounded 3-pin receptacles only.

5. Attach or disattach reflector, snoot, or other accessories after halogen lamp turned off and
    cooled off.

6. Be careful of electric shock when using this equipment in humid places.

7. Keep this equipment where children can not reach.

2. Name of Parts

3. Functions of Control Panel

¨ç Photocell : With slave on, operates with other
                    light

¨è Ready : Lighting test, lights up when pressed.

¨é Slave : Synchro sensor on/off switch

   - On(Green lamp on) : Operated by synchro

                                   sensor or synchro cord

   - Off(Green lamp off) : Operated by synchro

                                   cord only.

¨ê Alarm : Alarm on/off switch

               (checking the charging status)

   - On(Green lamp on) : Beeps while being                     charged, stops beeping when over.

   - Off(Green lamp off) : Resets alarm

¨ë Power : Main power switch

                - On (Red lamp on)     - Off (Red lamp off)

¨ì Flash : Output lighting volume control (1/8 Minimum - 1/1 Maximum)

¨í Model : Modeling lamp lighting volume control (  Minimum -  Maximum)

4. Operation

1. All powers are lowered, and lighting volume is    minimised when a flash was released from
   the factory.

2. Check the modeling lamp volume, flash volume, and the power is turned off before power on.

3. Connect synchro cord to the synchro socket.

4. Turn on power button(Red lamp on).

5. Never forget to discharge the remaining electric currency before turns off the mail power.

5. Maintenance and keeping mehod

1. How to replace modeling lamp(BASE:E-11 or E-27)

   - Cool off and then take out the modeling lamp.

   - Be careful not to leave fingerprints or stains on the lamp, clean up the surface of lamp after

     replacement.

2. How to replace a fuse

   - First take out the electricity cord.

   - Disassemble fuse holder and take out the fuse.

   - Check the fuse is short and replace a spare fuse in the fuse holder.

3. How to keep flashes

   - Protect pirex dome and xenon tube from dust or stain while being kept

   - If there are dust or stain on the pirex dome or xenon tube which lifetime might be shortened
     or lead lower color temperature, clean up them with soft fabric.

 

¡Ø Remarks : It might not recharge fully when a rated voltage is higher than input voltage. In this
                   case, please check input voltage. This product can be modified for better quality
                   without prior notice.

6. Trouble shooting

STATUS

ESTIMATED CAUSE

TROUBLE SHOOTING

Photo cell does

not operate.

Cell is off.

Check whether cell is on or not.

The light does not reach photo cell.

Change the position of flash so that light can reach the photo cell

Too much light shines photo cell.

Isolate the flash from very strong light.

Synchro cord

does not operate.

Dust or stain on the synchro cord jack

Remove dust or stain

Shortened synchro cord or bad connection

Replace it (Check whether it turns on or not by pressing test button)

No operation

No electricity

- Check if the electricity cord is well  inserted.

- Check if the contact of consent is OK.

- Check the fuse.

Others

Please consult a dealer or manufacturer.  They will provide you safety, insure proper operational functions and provide continuation of your warranty.